Operating Temperature
|
-10°C – 65°C
|
Storage Temperature
|
-25°C – 80°C
|
Processing System
|
Multi-task (High-speed, multiprocessing)
|
(*) Memory Capacity
|
4 GB (2 GB for logging data)
|
Function Setting
|
Using CICON software (PLC Loader Program)
|
CM1-CPU
|
Connection Method
|
Connection with RS-232C port
or USB at CPU module
Passthru connection through
communication module (EC Series)
|
Configuration
|
Network setting, logging type,
logging cycle, data list, Log file ID (*)
|
Monitoring
|
The number of clients,
communication status, logged data
transmission status, progress of data logging,
CPU status, memory consumption(%),
memory overflow (Automatic dump, deletion)
status, error information
|
Communication Function
|
Communication Standard
|
Ethernet 10/100 Mbps or 1 Gbps
|
Protocol
|
TCP, CIMON HMI Ethernet Protocol
|
Access Limitation
|
Simultaneous connections of up to 5 clients
(Up to 3 clients can simultaneously
access when using FTP feature)
|
Comm. Cable
|
Over CAT.5 STP (Shielded Twisted pair) cable
|
Max. Distance
|
Maximum 100 m for preliminary physical connection with the network device
(host system, hub, router, etc.)
|
Logging Function
|
Logging Type
|
Event Sampling, Trigger Monitoring (*)
|
Range of Cycle
|
1 – 327,67 (x L ms)
L(*) = Time interval scale (1, 10, 100),
The value is fixed at L = 10 in under V2.0
|
Range of Deadband
|
0 – 65535(*)
The value is fixed at ‘0’ in under V2.0.
|
Logging Device Type
|
X, Y, M, L, K, F, T, TC, TS, C, CC,
CS, S, D, Z, R Device in PLC CPU
|
Data Type
|
Bit, Byte, Word, DWord, DDWord
|
Data Storage
|
Non-volatile memory (ROM) storage
(Does not require a battery)
|
Data Capacity
|
24Byte for saving in the device type
|
Data Managing
|
Storage Method
|
Event sampling: Saving data by date/hour
Trigger monitoring (*): Saving data by file ID
(Including time information)
|
Delete Method
|
Automatic delete: The oldest data is deleted when
memory is at capacity (Overflown)
Manual delete: All logged data, (*) event sampling log data, (*) trigger monitoring log data
|
Compatible Host System
|
SCADA V3.90 and above version including ‘Historian’ feature
Recommended system requirements: 64-bit version of Windows, 8 GB RAM
|
Range of Time Synchronization
Frequency
|
1 – 32767 (x10 sec)
|
Error Display
|
LED, Display error code
(LG02G configuration/monitoring window in CICON)
|
Comm. Status Display
|
LED, Display error code
(LG02G configuration/monitoring window in CICON)
|
Number of I/O points
|
16 points
(Input 16 points/output 16 points)
|
Current Consumption
|
136 mA
|
Weight (g)
|
113.5
|