Technical specifications |
ELECTRIC |
Supply | 115/230 Vac ± 10%, 50 - 60 Hz |
Absorption max. | 1.5 VA |
Isolation | • Power supply // Inputs // Outputs: 4.500 Vac. • Input // Outputs S112M: 2,000 Vac. |
Paper Feed. transducers | 20 Vdc not stabilized |
Status indicators | • Supply • Pulse input / output |
Installation category | II |
Degree of pollution | 2 |
Degree of protection | IP20 |
Connections | Screw terminals for conductors up to 2.5 mm2 |
THERMOMECHANICAL |
Operating temperature | -10 +60 ° C |
Humidity | 30-90% at +40 ° C (non-condensing) |
dimensions | 52.5 x 95 x 72 mm (S112A), 70 x 95 x 72 (S112D, S112M) |
Weight | About 250 g (S112A), about 270 g (S112D), about 280 g (S112M) |
custody | Type DIN 3 (S112A) - 4 (S112D, S112M) modules in self-extinguishing Noryl |
mounting | Mounting on profile 35 mm DIN 46277 |
ORDER CODES |
Template | On-off sensor amplifier power supply |
Supply | 24 Vac/dc |
CONFIGURATION AND STANDARDS |
DIP switch | Division factor |
Settings | • Divider circuit with programmable division factor from 1 to 256 through DIP-switch (S112A, S112M). • Output pulse of 20 ms. 1 s (S112M). |
CE standards | EN50081-2, EN50082-2, EN61010-1 |