Specifications |
Parameters |
Temperature Range | -20°C to 1000°C, varies by model (see "Ordering") |
Output | 4-20 mA or RS485 Modbus* |
Field of View | Choice of wide-angle or focussed optics (see Field of View Diagrams below) |
Accuracy | ± 1°C or 1%, whichever is greater |
Repeatability | ± 0.5°C or 0.5%, whichever is greater |
Emissivity Setting | Adjustable, 0.20 to 1.00 |
Emissivity Setting Method | -CB models: via two rotary switches in electronics module -BB and -BRT models: via RS485 Modbus -CRT and -BRT models: via touch screen |
Response Time, t90 | 240 ms (90% response) |
Spectral Range | 8 to 14 µm |
Supply Voltage | 24 V DC ± 5% |
Maximum Current Draw | 100 mA |
Max. Loop Impedance (-CB and -CRT models) | 900 O (4-20 mA output) |
Alarm Relays (-CRT and -BRT models) | 2 x Single Pole Changeover alarm relays, rated 24 V DC, 1 A, isolated 500 V DC |