Technical Specifications |
MIV-18 |
Current Requirements: | 30mA (exclusive of load) |
Remote AUTOSET Input: | Opto-isolated momentary sinking input (10 milliamps) |
Response Time: | Light State response = 600µs (1,100µs, Thru-Beam)Dark State response = 600µs (1,100µs, Thru-Beam) |
Light/Dark "ON" Operation: | Light “ON” achieved by connecting white wire to negative leadDark “ON” achieved by connecting white wire to positive lead |
Range: | Dependent on model, see Selection Guidelines Note: 5 VDC models, range reduced by 10% |
Hysteresis: | Approximately 20% of signal |
Light Immunity: | Responds to sensor’s pulse modulated light source, resulting in high immunity to most ambient light, including high intensity strobes |
Diagnostic Indicators: | Red LED = Output StatusGreen LED = Power “ON” |
Ambient Temperature: | -40°C to 70°C (-40°F to 158°F) |
Rugged Construction: | Chemical resistant, high-impact polycarbonate housingWaterproof ratings: NEMA 4X, IP66 |