| Technical data |
| General Data |
| Power supply | 7..30 Vdc |
| Hot swapping | Yes |
| Current consumption | 24 mA |
| Power consumption | <660 mW |
| A/D Conversion | 16 bit |
| Rejection | 50 o 60 Hz (configurable) |
| Settings | 50 o 60 Hz (configurable) |
| Filter | Added for stable reading |
| Isolation | 1,5 KVac (3-way) |
| Isolation technique | Digital (optocoupler) |
| Data processing | 32 bit floating point |
| Enclosure | PBT |
| Weight | 45 g |
| Connections | 8 Clamp terminals |
| Precision class | 0,10% |
| Thermal drift | <120 ppm/K |
| Status Indicators | Fault,alarm |
| Programming | PC software EASY SETUP / EASY LP (by TTL port and EASY-USB or S117P1 converter) |
| Advanced settings | Start / End of measuring scale 2/3/4 wire RTD connection Measuring filter Normal (4 ..20 mA) or inverted output (20 ..4 mA) Input type selection Cable resistance compensation for 2-wire measurement Setting output value in case of fault Over-range Cold junction compensation |
| Protection Degree | IP20 |
| Operating |
| Temperature | -20..+65 °C |
| Dimension | (W x H x ) 6,2 x 93 x 102,5 mm |
| Input Data |
| Channel Numbers | 1 |
| Type | THERMOCOUPLE J,K,R,S,T,E,B,N,L (EN 60584 RTD (Pt100, Pt500, Pt1000, Ni100, NI120, NI1000, Cu50, Cu100) 2, 3, 4 wires connection Voltage (V) ± 30V, impedance 200 kO Voltage (mV) ±150 mV, impedance 10 MO Current: ±24 mA, impedance 40 O Potentiometer: 500 O..10 KO Resistance: up to 1760 O |
| Output Data |
| Channel Numbers | 1 |
| Type | Current 4..20mA |
| Response time(10-90%) | 140..620ms |
| Standard |
| Approval | CE, II 3G Ex nA IIC T4 Gc X, II 3D Ex tc IIIC T135°C Dc X |
| Norms | Safety (EN 61010-1), EMC (EN 61000-6-2, EN 61000-6-4, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN61000-4-5, EN 61000-4-6, EN 61000-4-11), Atex (EN60079-0, EN 60079-15) |