| Specifications |
| CAN Interface |
| Transceiver | NXP 82C250 | AMIS 41682 |
| Channel number | 1 |
| Connector | 9-pin male D-Sub (CAN_L, CAN_H, N/A for others) |
| Baud Rate (bps) | 10 k, 20 k, 50 k, 125 k, 250 k, 500 k, 800 k, 1 Mbps | 10 k, 20 k, 50 k, 125 kbps |
| Isolation | 3000 VDC for DC-to-DC, 2500 Vrms for photo-couple | NONE |
| Terminator Resistor | Selectable 120O terminator resistor by jumper | 1 kO for CAN_H and CAN_L |
| Specification | ISO-11898-2, CAN 2.0A and CAN 2.0B | ISO-11898-3 (low speed fault tolerance), CAN 2.0A and CAN 2.0B |
| Receive Buffer | 1000 data frames |
| RS-232 Interface |
| Connector | 9-pin female D-Sub (TxD, RxD, GND, N/A for others ) |
| Baud Rate (bps) | 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200bps |
| Data bit | 5, 6, 7, 8 |
| Stop bit | 1, 2 |
| Parity bit | None, Even, Odd |
| Receive Buffer | 900 data frames |
| LED |
| Round LED | ON LED: Power and Data Flow; ERR LED: Error Status |
| Power |
| Protection | Power reverse polarity protection, Over-voltage brown-out protection |
| Power Consumption | 1 W |
| Mechanism |
| Installation | DIN-Rail |
| Dimensions | 72mm x 118mm x 33mm (W x L x H) |
| Environment |
| Operating Temp. | -25 ~ 75° C |
| Storage Temp. | -30 ~ 80° |
| Humidity | 10 ~ 90% RH, non-condensing |