| Specifications |
| Digital Input |
| Channels | 3-axis |
| Contact | Wet |
| Sink/Source (NPN/PNP) | Sink |
| Resolution | 32-bit |
| Max. Speed | 1 MHz |
| On Voltage Level | 5 V: +3.5 ~ +5 VDC 12 V with 1 kO External Resistor: +5 ~ +12 VDC 24 V with 2 kO External Resistor: +7 ~ +24 VDC |
| Off Voltage Level | +2 VDC Max. |
| Encoder Mode | CW/CCW, Pulse/Dir, AB Phase |
| Virtual Battery Backup for Counter Value | Yes |
| Communication |
| Channels | RS-485 |
| Bias Resistor | No (Usually supplied by the RS-485 Master. Alternatively, add a tM-SG4 or SG-785.) |
| Format | N, 8, 1 |
| Baud Rate | 1200 to 115200 bps |
| Protocol | DCON |
| Dual Watchdog | Yes, Module (1.6 Seconds), Communication (Programmable) |
| LED Indicators/Display |
| System LED Indicator | Yes, 1 as Power/Communication Indicator |
| 5-digit LED Display | Yes |
| Isolation |
| Intra-module Isolation, Field-to-Logic | 3000 VDC |
| EMS Protection |
| ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal |
| EFT (IEC 61000-4-4) | ±4 kV for Power Line |
| Power |
| Reverse Polarity Protection | Yes |
| Input Range | +10 ~ +30 VDC (non-regulated) |
| Consumption | 1.7 W Max. |
| Mechanical |
| Dimensions (L x W x H) | 123 mm x 72 mm x 35 mm |
| Installation | DIN-Rail or Wall Mounting |
| Environment |
| Operating Temperature | -25 to +75°C |
| Storage Temperature | -30 to +80°C |
| Humidity | 10 to 90% RH, Non-condensing |