| Technical specifications |
| Hardware |
| Controller | High Performance Microcontroller |
| RTC (Real Time Clock) | No |
| Watchdog | Watchdog IC |
| ESD Protection | 4 kV Contact for each channel |
| CAN Interface |
| Transceiver NXP | TJA1042 |
| Channel number | 4 |
| CAN Connector | 9-pin male D-Sub with CAN_GND, CAN_SHLD, CAN_H, CAN_L |
| CAN Specification | ISO-11898-2, CAN 2.0A and CAN 2.0B |
| Baud Rate (bps) | 5k, 10 k, 20 k, 33.3 k, 50 k, 62.5 k, 83.3 k, 125 k, 250 k, 500 k, 800 k, 1 M bps and user-defined |
| Baud Rate Selection | Selectable by rotary switch |
| Isolation | 3000 VDC for DC-to-DC, 2500 Vrms for photo-couple |
| Terminator Resistor Selectable | 120O terminator resistor by internal jump |
| Transmission Distance (m) | Depend on baud rate (for example, max. 1000 m at 50 kbps ) |
| CAN Filter | Configurable by user |
| UART Interface |
| RS-232 | 1 port (for configuration) |
| RS-232 Connector | 9-pin screwed terminal block (TxD, RxD, GND ) |
| LED |
| Round LED CAN | status LED x 4 , Power LED x 1 |
| Power |
| Input range Unregulated | +10 ~ +30 VDC |
| Power Consumption | 1.5W |
| Mechanism |
| Installation | Wall-Mounting |
| Casing | Aluminum metallic case |
| Dimensions | 116.5 x 127 x 61.3 mm (W x L x H) |
| Environment |
| Operating Temp. | -25 ~ 75 ? |
| Storage Temp. | -30 ~ 80 ? |
| Humidity | 10 ~ 90% RH, non-condensing |
| ESD protection | 4 kV Contact for each channel |
| EFT protection | 500V for signal, 1000V for power |
| EMI certification | 30M ~ 1G pass |
| Hi-pot protection | 1kV pass |
| Surge protection | 1kV pass |