GL100-N Main Unit Specifications |
Number of channels: | Varies by the input module used, and measurement type is fixed with each input module |
Output signal: | Alarm (1 channel), solid state switch with optical isolation (Optocoupler, Max. load is the 30 V, 50 mA) |
Interface to PC: | USB (micro USB B type connector) |
Storage device: | Built-in memory: RAM (Approx. 4.9 MB) External memory: microSD memory card * Maximum file size for captured data is 1.9MB. It is recommended to use the microSD memory card that supports sleep mode. (Example: TS4GUSDHC4, made by Transcend) |
Display | LCD (backlit monochrome, graphical type 128 x 64 dots) Contents: Captured data and Setting menu (Stored data is not able to replay. It is able to replay using the PC application software.) |
Functions: | Real-time data capturing Display the captured data value to the LCD in real-time and save the monitoring values Set conditions using the Menu setting |
While using USB port: Output captured data in real-time Output the saved data from the internal memory Full control of the GL100 from the PC application software |
Alarm: | Action Outputs the signal when the measuring data reaches the present conditions of alarm Source Level of measuring data Detecting method Condition: Higher or lower (signal is higher or lower than the threshold) Combination: or |
Trigger: | Action Start or stop the recording of captured data by trigger Source Start trigger: OFF, Level (*), Alarm, or Date Stop trigger: OFF, Level (*), Alarm * Level trigger is available in the analog input of the GS-4VT, GS-4TSR, and GS-3AT module. Detecting method of the Level (*) Condition: Rising or Falling (signal is passed through the threshold) Combination: OR or AND |
Dustproof and waterproof: | IP54 compatible (*) * It is effective only in the condition that the input module is set to the GL100 and then the covers of connector and battery are closed. It is recommended to replace the packing of cover in periodically. |
Power source: | Alkaline battery (AA size x 2) USB bus-power (5V, 200 mA) (*) * When AC adapter for USB device is used, the required power capacity is 5V, 1A. Battery and AC adapter is not included. |
Operating environment: | Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) |
External dimension [W x D x H]: | Approx. 66 x 100 x 27 mm (exclude protrusion |
Weight: | GL100-N: Approx. 125 g |
GS-DAP-AC Current Sensor Adapter Specifications |
Number of sensors: | Two (2) sensors |
Connectable sensors: | GS-TH (Temp./Humidity), GS-CO2 (Carbon dioxide (CO2)), GS-LXUV (Illuminance and Ultraviolet); It is not able to connect two sensors of the same type. |
Length of cable: | Approx. 200 mm |
Operating environment: | Temperature: -10 °C to 50 °C; Humidity: up to 80 % RH (non condensed) |
External dimension [W x D x H]: | Approx. 46 x 66 x 27 mm (exclude protrusion) |
Weight: | Approx. 68 g |
GS-TH Temperature and Humidity Sensor Specifications |
GS-TH: | Relative Temperature and Humidity Sensor |
Measurement Data: | Temperature, Humidity, Dew Point Temperature (calculated value) Accumulated Temperature ºCh Accumulated Temperature only recorded |
Measurement Range: | ±2G (20 m/s2, ±5 (50 m/s2, ±10 (100 m/s2) (Gravitational Acceleration 1G = approx. 9.807 m/s) |
Measuring Method: | C-MOS sensor |
Range of Temperature Measurement: | -20º C to 85º C |
Temperature Measurement Degree of Accuracy: | -20 =TS < 0 ±0.8(ºC) 0 =TS < 60 ±0.5(ºC) 60 < TS =85 ±0.8ºC |
Range of Humidity Measurement: | 0.0 - 100.0% RH |
Humidity Measurement Accuracy: | At 25º C; ±1.0% RH (0-10% RH) ±8% RH (10-20% RH) ±5% RH (20-80% RH) ±8% RH (80-90% RH) ±10% RH (90-100% RH) |
Response Time (Temperature): | Temperature, Humidity: approx. 100 seconds to reach 63% at 25ºC with airflow speed of 1m/s(1) |
Processor Functionality: | Accumulated Temperature: 0 to 999,999kº ch(2) |
Memory Capacity (Memory Mode): | 16 | 32 | 64 | 128k sample |
Pre-trigger (Memory Mode): | OFF/10 | 25 | 50 | 100% of selected memory |
Sampling Interval: | 0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec 1 | 2 | 5 | 10 | 20 | 30 | 60 min |
Alarm: | OFF/level |
Temperature Unit of Denomination: | ºC/ºF (selectable) |
Waterproofing: | Waterproof protection filter at the connection point. |
Operating Environment: | Within range of Temp/Humidity measurement. |
External Dimensions: | 15 mm x 45 mm x 10.2 mm (excludes protrusion) |
Weight: | Approx. 14g (0.49 oz) |
GL-LXUV Illuminance and UV Sensor Specifications |
GS-LXUV: | Luminance (0 lux to 200k lux) and UV rays (0 to 30 mW/cm2) Dual sensor module |
Measurement Data: | Luminance, UV ray strength, Accumulated Luminance Accumulated UV ray strength |
Measurement CH: | Luminance | 1-ch |
UV Ray | 1-ch |
Measurement Range: | Luminance | 0 lux to 200k lux |
UV Ray | 0 to 30 mW/cm2 |
Measurement Degree of Accuracy: | Luminance | ±5% |
UV Ray | ±5% |
Spectrum of Accuracy: | Luminance | 400 to 750 nm (peak 560 nm) |
UV Ray | 260 to 400 nm (peak 370 nm) |
Measurement Resolution: | Luminance | 0.1 lux |
UV Ray | 0.001 mW/cm2 |
Response Time: | Luminance | 1 ms or less |
UV Ray | 1 ms or less |
Processor Functionality: | Luminance | 0 to 999,999 klxh |
UV Ray | 0 to 999,999 W/cm2 |
Sampling Intervals: | 0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec 1 | 2 | 5 | 10 | 20 | 30 | 60 min |
Extension Cable: | Approx. 200 mm |
Operating Environment: | -10º to 50ºC, 80% RH and below (non-condensed) |
External Dimensions: | 46 mm x 66 mm x 19 mm (excludes protrusion) |
Weight: | 65g (2.29 oz) |