Item | Description |
Number of channel | Up to 4 channels |
Interface to PC | USB 2.0 |
Functions | Real-time data capturing Display the captured data value to the LCD in real-time and save the monitoring values Set conditions using the Menu setting |
While using USB port: Output captured data in real-time Output the saved data from the internal memory Full control of the GL100 from the PC application software |
Display | LCD (backlit monochrome, graphical type) |
Storage device | Built-in RAM (Approx. 4.9 MB) micro SD memory card * Maximum file size for captured data is 1.9 GB. |
Sampling interval | 0.5 to 30 seconds and 1 to 60 minutes |
Output signal | Alarm (1 channel) |
Power source | Battery (AA x 2) USB bus-power (micro USB connector) * The required power capacity is 5V, 1A when AC adapter for microUSB drive is used. AC adapter is not included. |
Operating environment | Temperature: -10 ºC to 50 ºC Humidity: up to 80% RH (non condensed) Water resistance: IP54 |
External dimension | Approx. 66 x 100 x 27 mm (exclude protrusion) |
Weight | GL100-N: Approx. 125 g, GL100-WL: Approx. 130 g |
Temperature & Humidity sensor (GS-TH) |
Type of measurement | Temperature, and Humidity Accumulated temp. (calculated value), Dew-point temp. (calculated value) |
Measuring range | Temperature: -20 to 85 ºC Humidity: 0 to 100 % RH |
Acceleration & Temperature sensor (GS-3AT) |
Type of measurement | Acceleration in 3-axis (X-, Y-, Z-axis), and Temperature |
Measuring range | Acceleration: ±2 (20 m/s²), ±5 (50 m/s²), ±10G (100 m/s²) Temperature: -10 to 50 ºC |
Sampling interval | 5 to 100 ms in memory mode, 0.5 s to 60 min. in direct mode (*¹) |
Illuminance & Ultraviolet sensor (GL-LXUV) |
Type of measurement | Illuminance, and UV intensity Accumulated Illuminance (calculated value), Accumulated UV intensity (calculated value) |
Measuring range | Illuminance: 0 to 200 klx UV intensity: 0 to 30 mW/cm² |
Carbon dioxide (CO2) sensor (GL-CO2) |
Type of measurement | Carbon dioxide concentration |
Measuring range | 0 to 9999 ppm |
Operating environment | Temperature: 0 ºC to 50 ºC, Humidity: up to 80% RH (non condensed) |
AC Current sensor adapter (GS-DPA-AC) |
Type of measurement | Current Power (calculated value), Electric energy (calculated value) |
Application circuit | Single-phase two-wire, Single-phase three-wire system, or Three-phase three-wire |
Sensor | Clamp-on current probe (optional), Two (2) sensors are able to connect |
Measuring range | 50, 100, 200 A RMS (varies by the sensor) |
Voltage & Thermocouple input terminal (GL-4VT) |
Number of channel | Analog voltage 4 channels, Logic or Pulse 4 channels (*²) |
Measuring range | Voltage: 20mV to 50V, 1-5V FS Thermocouple: K type (-200 to 1370 ºC) & T type (-200 to 400 ºC) Logic (signal pattern): 0 to 24 V (common ground) Pules (count): Max. 200 counts/sampling intervall, accumulating up to 65535 counts |
Temperature sensor input terminal (GL-4TSR) |
Number of channel | Sensor 4 channels, Logic or Pulse 4 channels (*²) |
Sensor | Thermistor sensor (optional) |
Measuring range | Temperature: -40 to 120 ºC (varies by the type of sensor) Logic (signal pattern): 0 to 24 V (common ground) Pulse (count): Max. 200 counts/sampling interval, accumulating up to 65535 counts |